This page was exported from Latest Exam Prep [ http://certify.vceprep.com ] Export date:Sat Sep 21 11:49:41 2024 / +0000 GMT ___________________________________________________ Title: Study HIGH Quality H12-425_V2.0-ENU Free Study Guides and Exams Tutorials [Q10-Q26] --------------------------------------------------- Study HIGH Quality H12-425_V2.0-ENU  Free Study Guides and Exams Tutorials Download Huawei H12-425_V2.0-ENU Exam Dumps to Pass Exam Easily NO.10 In the UPS5000 configurator, what are the optional module types? (Multiple choice)  50k high efficiency  25k  50k standard effect  60k NO.11 What are the alarm management functions supported by the ECC800? (Multiple choice)  View historical alarms  Filter alerts  Alarm data export  Alarm parameter setting NO.12 What is the maximum IT load supported by the FusionModule2000 integrated UPS?  50kW  125kW  150kW  75kW NO.13 FusionModule800 can only support down pipe.  True  False NO.14 When installing the UPS500-E, a certain distance should be left behind and above to ensure ventilation and heat dissipation.  True  False NO.15 NetEco6000 management system can realize APP + intelligent inspection, greatly reducing operation and maintenance man-hours.  True  False NO.16 What are the optional functions in PDU8000? (Multiple choice)  Input switch remote tripping function  Temperature Monitoring Feature Function  Branch switch hot swap function  9 earthquake resistance NO.17 What is a gas fire extinguishing device composed of? (Multiple choice)  Fire Air  Pressure switch  Sound and light alarm  Solenoid valve NO.18 In UPS, corresponding to 50k modules, the maximum output capacity of a single UPS is?  500kVA  400kVA  800kVA  600kVA NO.19 UPS5000-A has built-in SNMP and ModBus card, which reduces the management investment cost of customers.  True  False NO.20 When the battery is discharged, the discharge voltage of a faulty battery drops rapidly, and the backup time of the entire battery rented in the morning is not enough, so it should be dealt with ().  Force equal charge, replace the faulty battery  No processing required  Scrap the entire battery pack  to discharge NO.21 UPS2000-G- (6-20KVA) battery is not connected, which does not affect the normal power supply of the system.  True  False NO.22 If the NETCOL5000-A air-conditioning unit operates abnormally, you should check whether the compressor, fan, and pipe lights are fixed properly and whether there is any looseness.  True  False NO.23 The FusionModule2000 battery is listed in the scene, supporting up to () battery cabinets?  4  6  2  8 NO.24 The dry contact signal of UPS5000-E does not support the remote emergency stop function.  TRUE  FALSE NO.25 The UPS5000-E power chess block adopts a fan fault-tolerant design. When two of the fans are damaged, what percentage of the power module can still be loaded?  0.3  0.5  0.2  0.6 NO.26 Huawei’s main temperature control solution for small and medium-sized computer rooms is?  Row-level chilled water with micro-modules  Room-level air cooling solution  Room-level chilled water solution  Row-level air cooling with micro-modules  Loading … Get 100% Real Free HCIP-DCF-BFDO H12-425_V2.0-ENU Sample Questions: https://www.vceprep.com/H12-425_V2.0-ENU-latest-vce-prep.html --------------------------------------------------- Images: https://certify.vceprep.com/wp-content/plugins/watu/loading.gif https://certify.vceprep.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2023-05-08 14:01:47 Post date GMT: 2023-05-08 14:01:47 Post modified date: 2023-05-08 14:01:47 Post modified date GMT: 2023-05-08 14:01:47